Contour Next One Blood Glucose Monitoring System Set
zoom_in Click to zoom
Contour Next One Blood Glucose Monitoring System Set
AED129.00
Inclusive of VAT
AED139.00
7% Off
Inclusive of VAT
To be delivered within 2 business days
Shipping/Delivery
2Payment Option
Cash-on-delivery
Return Policy
30 day returns. Buyer pays for return shipping. Terms & conditions apply.
Product Description
The CONTOUR NEXT ONE meter offers seamless connection to the CONTOUR DIABETES app to capture all your blood glucose readings. How to use Insert the grey end of a CONTOUR NEXT test strip into the meter. The meter will turn on. When the Apply Blood screen appears, touch the test strip to the drop of blood. Hold it there until the meter beeps. Your test result will appear after a 5 second countdown and you will be prompted to add a meal marker. The smartLIGHT will then indicate whether your reading is within, above, or below target range. Hazards and cautions • Read your Contour Next ONE user guide, the lancing device package insert, if provided, and all instructional materials provided in your meter kit before testing. Follow all instructions for use and care exactly as described to help avoid inaccurate results. • Examine the product for missing, damaged, or broken parts. If the test strip bottle is open inside a new box of strips, do not use those strips. For replacement parts, contact Diabetes Care Customer Service. See the back cover for contact information. • Your Contour Next ONE meter works ONLY with Contour Next test strips and Contour Next control solution. Always keep the Contour Next test strips in their original bottle. Tightly close the bottle immediately after removing a test strip. The bottle is designed to keep the test strips dry. Do not place or store other items or medications in the test strip bottle. Avoid exposing meter and test strips to excessive humidity, heat, cold, dust, or dirt. Exposure to room humidity by leaving the bottle open or not storing the strips in their original bottle can damage your test strips. This could lead to inaccurate results. Do not use a test strip that appears damaged or has been used. • Do not use expired materials. Using expired material can cause inaccurate results. Always check the expiration dates on your test materials. NOTE: If this is the first time you are opening the control solution, write the date on the bottle. • Do not use control solution that is more than 6 months past the date you first opened the bottle. • If your control solution test result is out of range, contact Diabetes Care Customer Service. See the back cover for contact information. Do not use the meter for blood glucose testing until you resolve this issue. • The meter is designed to give accurate blood testing results at temperatures between 41°F and 113°F. If meter or test strip is outside this range, you should not test until the meter and test strip are within this range. Whenever the meter is moved from one location to another, allow approximately 20 minutes for the meter to adjust to the temperature of the new location before performing a blood glucose test. • Do not attempt to perform a blood glucose test when the Contour Next ONE meter is connected to a computer. • Use only approved equipment from the manufacturer or certified body such as UL, CSA, TUV, or CE. Your Contour Next ONE meter has been preset and locked to display results in mg/dL (milligrams of glucose per deciliter of blood). v Results in mg/dL will never have a decimal point. v Results in mmol/L will always have a decimal point. Example: or v Check your display screen to be sure the results are shown correctly. If not, contact Diabetes Care Customer Service. See the back cover for contact information. • The Contour Next ONE blood glucose monitoring system has a measuring range of 20 mg/dL to 600 mg/dL. v For results over 600 mg/dL or under 20 mg/dL: o If your blood sugar reading is under 20 mg/dL, the meter displays the LO screen. Contact your health care professional immediately. o If your blood sugar reading is over 600 mg/dL, the meter displays the HI screen. Wash your hands or the test site. Repeat the test with a new strip. If results are still over 600 mg/dL, follow medical advice immediately. Important info Talk to Your Health Care Professional: • Before setting any Target Ranges in the Contour Diabetes app. • Before changing your medication based on test results. • If your blood sugar reading is under 50 mg/dL follow medical advice immediately. • If your blood sugar reading is over 250 mg/dL, or the critical level you have established with your health care professional: 1. Wash and dry your hands well. 2. Retest with a new strip. If you get a similar result, call your health care professional as soon as possible. • About whether Alternative Site Testing (AST) is appropriate for you. Potential Biohazard • Always wash your hands with soap and water and dry them well before and after testing or handling the meter, lancing device, or test strips. • All parts of the kit are considered biohazardous and can potentially transmit infectious diseases, even after you have performed cleaning and disinfection. For complete instructions on cleaning and disinfecting your meter and lancing device, see pages 47 to 50. • For more information about cleaning and disinfecting your meter or lancing device see: “US Food and Drug Administration. Use of fingerstick devices on more than one person poses risk for transmitting bloodborne pathogens: initial communication. US Department of Health and Human Services; update 11/29/2010.” http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ ucm224025.htm
Specifications
- Medical Supplies & Equipment Type: Blood Glucose Monitors
- Model Name: Contour Next ONE
- Medical Supplies & Equipment Brand: Ascensia